Welcome to Hong Kong CAS Testing ~

lang  CN

Our Services

Ozone resistance test of elastomer mixtures

Ozone resistance test of elastomer mixtures-Reliability Testing-

Test Background

Ozone resistance test, thermal extension test and mineral oil immersion test of elastomer mixtures are suitable for the insulation and sheathing of elastomer mixture materials for wires, cables and optical cables.
Zhongke Testing Reliability Experiment Center has environmental testing capabilities for various cables and optical cables, and provides professional ozone resistance testing, thermal extension testing, and mineral oil immersion testing services for elastomer hybrid materials.

Scope of tests

The most common types of insulation and sheathing materials for power distribution and communication cables and optical cables, wires and cords, including polymer insulation and sheathing materials for ship and offshore cables and optical cables, as well as insulation and sheathing materials for elastomers, polyvinyl chloride, polyethylene, polypropylene, etc.

Test method

1. Ozone resistance test:
After the specified test time is over, remove the specimen from the test chamber and inspect it using normal or corrected vision without a magnifying glass. There should be no cracks in the 180° bent portion of the insulation specimen farthest from the ligation point. The narrow strip in the middle of the dumbbell specimen shall be free of cracks.
2. Hot extension test:
After bearing the load for 10 minutes at the specified temperature, the intermediate value of the elongation should not be greater than the provisions of the relevant cable product standards; the intermediate value of the increase in the distance between the marked lines after the test piece is taken out of the oven and cooled, as a percentage of the distance before the test piece is placed in the oven, should not be greater than the provisions of the relevant cable product standards.
3. Sheath immersion mineral oil test:
The difference between the median value of the mechanical properties of the five specimens before and after oil immersion and the percentage of the median value of the mechanical properties before oil immersion should not be greater than the provisions of the relevant cable product standards.

Test standard:

GB/T 2951.21-2008 General test methods for insulation and sheath materials of electric and optical cables Part 21: Special test methods for elastomer mixtures - Ozone resistance test - Hot elongation test - Mineral oil immersion test
GB/T 2951.12-2008 General test methods for insulation and sheath materials of electric and optical cables Part 12: General test methods Thermal aging test method
GB/T 2951.11-2008 General test methods for insulation and sheath materials of electric and optical cables Part 11: General test methods—Measurement of thickness and dimensions—Mechanical properties test
IEC 60811-2-1: 2001 General test methods for insulation and sheathing materials of electric and optical cables Part 2-1: Special test methods for elastomer mixtures--Ozone resistance test--Thermal elongation test--Mineral oil immersion test
IEC 60811-403:2012 Electrical and optical cables - Test methods for non-metallic materials - Part 403: Miscellaneous tests - Ozone resistance test of cross-linked compounds
KS C IEC 60811-2-1-2006 Insulating and shielding materials for electrical and optical cables Application methods Part 2-1: Specific methods for elastomers Ozone resistance, thermosetting and mineral oil immersion tests
DIN EN 60811-403-2012 Electrical and optical cables Test methods for non-metallic materials Part 403: Miscellaneous tests Ozone resistance test of cross-linked compounds